The WEH® TK17 H2 70 MPa ENR with exchangeable nozzle receiver was developed for refueling cars with compressed hydrogen (CGH2).
The fueling nozzle provides the same proven characteristics as the actual known TK17 H2 70 MPa.

Exchangeable data interface
The IR data interface which is located at the front part of the fueling nozzle ensures proper communication between the vehicle and the fueling station thus achieving the optimum filling level.
So far the complete fueling nozzle has had to be sent in for repair in case of damage or malfunction of the data interface. With this version of the TK17 H2 70 MPa, however, the data interface can now be easily exchanged by specially trained personnel on the spot and within a very short time. Downtimes are reduced.

Prevent fueling nozzles from freezing on the receptacle - WEH anti-freeze technology
The WEH® TK17 H2 70 MPa ENR is equipped with a purging line to allow for the hose to be flushed out with nitrogen during or after the fueling process. This can prevent ingress of moisture and formation of ice crystals when filling with pre-cooled hydrogen. Removing the fueling nozzle from the receptacle is thus facilitated even in unfavorable climatic conditions.

The accompanying mounting is also equipped with a connection for flushing cycles and enables flushing of the fueling nozzle when not in use.

Optimal safety for the operator
The continuous rubber protection offers optimal protection not only for the vehicle and the front part of the fueling nozzle against damage, impacts and weather-related influences, but also for the operator against frostbitten hands.

The internal coding for pressure range and gas type ensures that the WEH® TK17 H2 70 MPa ENR can be connected to the compatible WEH® Receptacles and also prevents the risk of confusion with natural gas.

Technical Data
Nominal bore (DN)4 mm
Pressure rangePN = 70 MPa | PS = 87.5 MPa
Nominal pressure (PN)70 MPa
Media temperature range-40 °C up to +85 °C
Ambient temperature range-40 °C up to +85 °C
Media inlet B1UNF 9/16"-18 male thread, 60° inner cone
DesignWith plastic thermal protection, cold protection, hand grip with magnet,
exchangeable data interface acc. to SAE J2799 and integrated purging line
MaterialCorrosion resistant
Sealing MaterialHydrogen resistant
Nozzle typeType C acc. to SAE J2600:2015 and previous resp. ISO 17268:2012 and previous
Medium noteSuitable for pre-cooled hydrogen
Gas recirculationUNF 7/16"-20 male thread, SAE J514, 37° cone
WeightApprox. 2.9 kg
Medium for purgingNitrogen
Nominal bore (DN) of purging line4 mm
Media temperature range of purging medium-20 °C up to +85 °C
Flow rate during purging500 Nl/h at max. 12 bar purging pressure
Conformity / Tests / ApprovalsFueling nozzle: tests acc. to SAE J2600:2002
IR data interface: SAE J2799 and ATEX
Media Temperature Range -20 °C up to +85 °C
Coding for pressure range / gas type, Compatible to receptacle WEH® TN1 H2 70 MPa, Easy operation, Exchangeable nozzle receiver (ENR), Hand grip with magnet, High flow rate -> short filling times, High-grade materials, Increased robustness, Integrated purging lin

Fueling nozzle for H2 fast filling of electric / hybrid cars with fuell cells (FCV) at self-service fueling stations.