WEH® Breakaway Coupling TSA30-S1 H₂ 70 MPa
The breakaway coupling is installed directly on the dispenser. In the event of unexpected tensile forces, such as a vehicle driving away with a connected fueling nozzle, the TSA30-S1 H2 70 MPa separates the connection between the dispenser and hose in a controlled manner. Both sides are sealed pressure-tight directly after breakaway and therefore damage to the vehicle and the dispenser can be prevented as far as possible.
The max. operating pressure of 96.25 MPa offers even more safety. If there is a malfunction, the safety valve of the dispenser opens at a pressure of 96.25 MPa. This high pressure can also reach the breakaway coupling, but the TSA30-S1 H2 70 MPa can withstand this pressure perfectly.
In the event of a breakaway, the base unit can be reused - no factory servicing is necessary. Only the receptacle insert needs to be replaced or serviced. Therefore we offer a replacement receptacle insert, to avoid downtime at the dispenser.
The WEH® Breakaway coupling consists of a base unit and a receptacle insert. The integrated fi lter ensures clean fi ltered hydrogen and thus prevents damage caused by dirt ingress.
The TSA30-S1 H2 70 MPa is suitable for use with pre-cooled hydrogen.
Nominal bore (DN) | 8 mm |
---|---|
Pressure range | PN = 70 MPa | PS = 96.25 MPa |
Media temperature range | -40 °C up to +85 °C |
Ambient temperature range | -40 °C up to +85 °C |
Design | With filter (5 μm) |
Material | Corrosion resistant stainless steel |
Sealing Material | Hydrogen resistant |
Weight | Approx. 3.3 kg |
Breakaway force | 220 - 1,000 N |
Conformity / Tests / Approvals | Tested acc. To ISO 19880-3 |
Breakaway coupling for hydrogen fueling stations for direct installation at the dispenser.
Description | Document type | Language | File type | File size |
---|